TITAN

Titan - Three Phase UPS system

BEST EFFICIENCY 3PHASE
100KVA ~ 500KVA
Taurus Online Double Conversion UPS system Features Power Factor 1 on all ratings, delivering 13% more active power than its competitors for the same kVA. With Digital Signal Processing(DSP), 3 level IGBT, smart battery discharge and strong overload capacity(300%) Taurus deliver clean, stable and reliable power for critical three-phase loads.

  Quote TITAN
Small/Medium datacenters
Small/Medium datacenters
Critical loads
Critical loads
Industry
Industry
Health Care
Health Care
Unity Power Factor ( kVA = kW)
Unity Power Factor ( kVA = kW)

The factor is to unity (1 pf) and hence the closer the two waveforms are in phase with each other, and the device uses power more efficiently.

• No power downgrading when supplying the latest generation of servers (leading or unity power factor).

• Real full power, according to IEC 62040: kW=kVA (unity power factor design) means 13% more active power available compared to legacy UPS.

• Suitable also for leading power factor loads down to 0.9 without apparent power derating.

High Efficiency -96%

UPS efficiency is based on how much of the original incoming power is needed to operate the UPS.

Higher efficiency equates to lower losses of electrical energy in terms of heat output – low efficiency UPS often require more air conditioning to help keep ambient temperatures safe. High efficiency offers direct, 24-houraday, energy savings, both within the UPS itself and indirectly through lower heat loads and even reduced building transformer losses .Titan offers high efficiency of 96% to minimize losses, decrease cooling requirements and increase savings

High Efficiency -96%
Battery Care System
Battery Care System

Data show that the proportion of UPS host failure or abnormal operation caused by battery failure is about 1/3. Therefore, it is more and more important to strengthen the proper use and maintenance of UPS batteryTitan’s smartcharging Battery Management System ensures UPS batteries are optimally charged and ready for use. By performing the charge equalization of every battery in a string, the product is able to maximize the battery lifespan and optimize the battery performance.

Generator Compatible

A generator typically produces inconsistencies and fluctuations in voltage and frequency ranges. Titan UPS continually converts incoming AC power – whether from the main power supply or a generator – into filtered DC power, and then reconverts it back into AC power with a pure sine wave. That’s the clean feed of power your sensitive equipment craves. And as another benefit, an on-line UPS filters variations in frequency as part of its everyday operation, so battery life doesn’t shorten prematurely.

Generator Compatible
Environment Monitoring
Environment Monitoring

Titan Environment Monitoring System record environmental conditions as well as activities in protected areas and at the premises where the UPS is installed.

The environmental sensors allow extensive control and management of the environment around the UPS by monitoring the temperature, humidity and communicating the values via web, SNMP